Zhejiang Weilan Technology Co., Ltd.

Technical Articles

Selection guides, maintenance notes and application stories

Technical Articles

Dosing Pump Tubing Size: 4 mm, 6 mm or Larger Discharge Lines

Choosing dosing pump tubing size starts with the pump head fitting. How to read ID x OD, when 4 mm bore is enough, when to go to 8-9 mm, and when to upsize a long line.

Technical Articles

Dosing Pump Tubing Material: PVC vs PE vs PTFE Compared

Choosing dosing pump tubing material by pressure, temperature and chemical: soft PVC, reinforced PVC, PE and PTFE ratings from ProMinent, and when to go rigid.

Technical Articles

Metering Pump VFD at Low Speed: Motor Cooling and Turndown

Can a metering pump VFD run a diaphragm pump slowly? Yes, within limits. Motor cooling sets turndown: 1:5 with PTC, 1:20 with a separate fan. Torque and accuracy too.

Technical Articles

Plunger Pump Gas Lock: Entrained Gas, Cavitation and Fixes

Why plunger pump gas lock happens with gassy chemicals, how to tell it from cavitation, and the piping, degassing and venting fixes that restore steady dosing.

Technical Articles

Plunger Pump Self Priming: Suction Lift and Flooded Suction

Is plunger pump self priming reliable? Learn what limits suction lift, how to prime a dry pump head and when a flooded suction is the safer design.

Technical Articles

Hydraulic Diaphragm Pump Refill Valve: Function and Setting

What the hydraulic diaphragm pump refill valve does, how under-refill and over-refill show up, and how to inspect, clean and set it without hurting the diaphragm.

Technical Articles

Chemical Dosing System Components: Tank to Injection Point

A practical list of chemical dosing system components: tanks, mixers, level sensors, metering pumps, relief and back pressure valves, dampers, gauges and controls.

Technical Articles

Metering Pump Volumetric Efficiency: Why Flow Drops With Pressure

What metering pump volumetric efficiency means, why real flow falls as back pressure rises, and how head design, diaphragm type and viscosity change the numbers you get.

Technical Articles

Inline Dilution Dosing System: Components, Piping and Pitfalls

How an inline dilution dosing system works: neat chemical pumped into a dilution water line, static mixer sizing logic, interlocks, back pressure and common mistakes.

Technical Articles

Dosing System Heat Tracing for Cold Climates: Where to Start

Where dosing system heat tracing matters most, from calibration columns and suction lines to injection points, plus enclosure options, chemical limits and level sensors.

245 items · Page 12 of 25