Zhejiang Weilan Technology Co., Ltd.

Technical Articles

Selection guides, maintenance notes and application stories

Technical Articles

Magnetic Flow Meter Installation: Straight Run, Full Pipe, Grounding

Magnetic flow meter installation for main-line water flow that paces chemical dosing: straight run, keeping the pipe full, grounding rings, bypass and signal checks.

Technical Articles

Coriolis Flow Meter for Chemical Dosing: Density, Pulsation, Install

Using a Coriolis flow meter on chemical feed: mass dosing, density-based strength checks, readings under metering pump pulsation, pressure drop and orientation.

Technical Articles

Blue-Green Algae Sensor vs Chlorophyll Sensor for Source Water

How a blue-green algae sensor and a chlorophyll sensor differ, how to set source water alarm levels from your own lab data, and which interferences fool the reading.

Technical Articles

Sample Conditioning System for Online Analyzers: Filter, Reduce, Cool

How to build a sample conditioning system for online analyzers: strainers, self-cleaning or cross-flow filters, pressure reduction, cooling and degassing.

Technical Articles

Ultrapure Water Conductivity: Bubbles and Carbon Dioxide

Ultrapure water conductivity is easily raised by bubbles and dissolved carbon dioxide. This note covers sealed sampling, why temperature compensation must be correct,.

Technical Articles

pH Electrode Poisoning from Sulfide, Oil and Protein Fouling

pH electrode poisoning often comes from sulfide, oil films or protein deposits, not from ordinary ageing. This guide shows how to tell the three apart, what can be.

Technical Articles

Dosing System Design Problems: What Breaks Between Drawing and Site

This guide covers dosing system design gaps between the drawing and the plant: suction lift, priming, pipe size, accessory space, and flush or calibration points.

Technical Articles

Conductivity TDS Conversion: Where the Factor Comes From

Conductivity TDS conversion has no universal factor. This note covers where 0.5 or 0.7 comes from, when the factor can be used, and when to report conductivity alone.

Technical Articles

Chemical Storage for Dosing: Shelf Life, Light, Heat and Segregation

Chemical storage for dosing should keep unopened packs and diluted solution apart, away from light and heat, with acids, alkalis and oxidisers kept in separate areas.

Technical Articles

Sodium Sulfide Dosing: Heavy Metal Precipitation and H2S Safety

Sodium sulfide dosing for heavy metal precipitation: H2S risk with acid, solution prep and storage, pump materials, ORP control and ferrous salt for excess sulfide.