ProMinent gamma/XL Solenoid Metering Pump (4 ml/h to 80 L/h): Selection & Setup

Author: Zhejiang Weilan Technology Co., Ltd.Source: Official sitePublished: Category: Selection Guide
Summary: Technical overview of ProMinent gamma/XL solenoid diaphragm metering pumps covering 4 ml/h to 80 L/h flow, 2 to 25 bar backpressure, and commissioning checks.

When chemical dosing rates sit between 30 and 80 L/h and you want digital solenoid control without gearbox oil changes, the German ProMinent gamma/XL fits well. Based on our ProMinent gamma/XL and gamma/X pages, here are the key limits and setup steps.

1. Core Specifications

ProMinent gamma/XL extends the gamma/X control platform to 4 ml/h to 80 L/h at 2 to 25 bar backpressure. High-pressure small heads reach 25 bar, while the 80 L/h head rates around 2 bar. Operators get direct L/h or mL/h setpoints, pulse pacing, 4-20 mA analog input, and overpressure diagnostics across PP, PVDF, PTFE, and stainless heads.

2. Suction Piping and Commissioning

Because 80 L/h models draw faster suction pulses, match the full factory tubing ID without reducers and use flooded suction where possible. Install a discharge backpressure valve (0.15 to 0.3 MPa) on open-tank lines and a safety relief valve upstream of isolation valves.

Conclusion

ProMinent gamma/XL bridges small solenoid pumps and motor-driven mechanical pumps up to 80 L/h without oil maintenance. Contact our team for backpressure curves or OEM spare kits.

FAQ

Can the 80 L/h gamma/XL model operate at 25 bar?

No. Flow and maximum backpressure trade off across model sizes; 25 bar applies to low-flow heads while 80 L/h models rate near 2 bar.

Can I enter flow setpoints directly in L/h?

Yes. Switch display units to L/h or mL/h in settings and run a drawdown calibration under operating pressure.

Is gamma/XL suitable for thick PAM polymer solutions?

Only for dilute low-viscosity polymers using slow-suction mode; choose a progressive cavity pump for viscous PAM.

Does gamma/XL detect a broken 4-20 mA loop?

Yes. In analog mode, input current below roughly 3.5 mA triggers a signal-loss fault.

Do you supply ProMinent gamma/XL pumps and repair kits?

Yes. Weilan supplies gamma/X, gamma/XL, and beta/X pumps along with genuine diaphragms and check valves.