Zhejiang Weilan Technology Co., Ltd.

Technical Articles

Selection guides, maintenance notes and application stories

Technical Articles

How a Polymer Dosing System Works: Dry Feed, Ageing and Delivery

How an automatic polymer dosing system works, step by step: dry powder feeder, water inlet and wetting head, three-tank dissolving, ageing and storage, level interlocks, and the feed pump to the process.

Technical Articles

PAC Dosing System: How It Works From Make-Up Tank to Injection Point

What a PAC dosing system is and how it works: dissolving or diluting PAC, the day tank, metering pumps, relief and back pressure valves, pulsation dampeners and control options, with the common site mistakes.

Technical Articles

Breakpoint Chlorination for Ammonia Removal: Estimating the Hypochlorite Dose

Breakpoint chlorination explained for wastewater plants: how chlorine converts ammonia to nitrogen gas, how to estimate the sodium hypochlorite dose from the chlorine to ammonia ratio, and why jar testing comes first.

Technical Articles

Boiler Phosphate Treatment: How It Controls Scale and Boiler Water pH

Boiler phosphate treatment turns residual hardness into soft sludge that blowdown can remove and keeps boiler water pH in a mildly alkaline, buffered range. Learn how trisodium phosphate works, signs of under- and overfeed, phosphate hideout, and dosing pump pitfalls.

Technical Articles

Boiler Chemical Dosing Calculation: How to Estimate Trisodium Phosphate Feed

A practical boiler chemical dosing calculation for trisodium phosphate: initial charge, blowdown makeup and hardness consumption, converted to product weight and metering pump flow. Includes unit traps and how to balance phosphate with caustic soda.

Technical Articles

Automatic Boiler Dosing: How Conductivity, pH and Flow Signals Drive the Pump

Automatic boiler dosing uses flow, pH and conductivity signals to tell a metering pump how much chemical to feed. Learn the parts of the system, proportional vs feedback control, how to wire 4-20 mA and pulse signals, and the interlocks that keep it safe.

Technical Articles

Dosing Pump Wiring: Power, Remote Control and Level Switch Connections

A field guide to solenoid dosing pump wiring: dedicated breaker and earth, dry-contact start/stop, pulse and 4-20 mA inputs, and low-level switch connections, plus the checks to run when a newly wired pump will not start.

Technical Articles

Solenoid Dosing Pump Installation: Foot Valve, Injection Valve and Vent Line

Solenoid dosing pump installation goes right or wrong on three small parts: the foot valve, the injection valve and the vent line. Where each goes, which way it faces, and the mounting, wiring and test sequence.

Technical Articles

Dosing Pump Calculation: Working Back From Flow to Stroke and Frequency

A practical dosing pump calculation: find the target flow, estimate volume per stroke, then solve for stroke length and strokes per minute. Includes why the numbers drift at short stroke and why you still calibrate.

Technical Articles

How to Read a Metering Pump Stroke Dial: Main Scale, Vernier and What the Percent Really Means

A metering pump stroke dial shows stroke length as a percent of full stroke, not liters per hour. Learn to read the main scale and vernier, why the number is only an approximation of flow, and the mistakes that throw readings off.

245 items · Page 21 of 25