Technical Articles
Selection guides, maintenance notes and application stories
Dosing Pump Working Principle: Why Low-Flow Chemical Feed Uses Reciprocating Pumps
The dosing pump working principle is positive displacement: each stroke pushes out a fixed volume, so flow is set by stroke length and rate, not by line pressure. See why centrifugal pumps fail at a few liters per hour, where reciprocating pumps fall short, and when another pump type makes sense.
Self Priming Metering Pump: What Diaphragm Pumps Can Lift and When to Use Flooded Suction
Is a diaphragm pump a self priming metering pump? Yes, within limits. Learn why air causes vapor lock, what rated suction lift really means, when to switch to flooded suction, and how to install a flooded inlet correctly.
Diaphragm Metering Pump Pressure Rating: What Sets the Limit
A diaphragm metering pump pressure rating depends on design. Mechanical diaphragms are limited by diaphragm area and drive force; hydraulic diaphragms balance oil pressure behind the membrane and go far higher. See how head material, valves and fittings cap the limit and how much margin to leave.
Chemical Dosing Calculation for Wastewater: From mg/L to Pump L/h
A step-by-step chemical dosing calculation for wastewater: turn plant flow and dose in mg/L into kg/h of active chemical, then into L/h of solution for the metering pump. Covers jar test conversion, active-basis traps, dilution and checking real usage.
How a Solenoid Dosing Pump Works: Electromagnet, Spring and Diaphragm
How a solenoid dosing pump works: an electrical pulse fires the solenoid, the armature pushes the diaphragm forward to discharge, and a return spring pulls it back to draw in chemical. Learn why flow is set by stroke rate, how control signals become strokes, and the limits.
Antiscalant Dosing Pump for RO: Getting Low-Flow Dosing Right
An antiscalant dosing pump on a small or mid-size RO plant often runs at the very bottom of its range. Learn how turndown, stroke length, injection back pressure, dilution and air locking decide whether the dose is accurate.
How a Plunger Metering Pump Works: Check Valves, Stroke Length and Packing
How a plunger metering pump works: a motor-driven crank moves a plunger in a cylinder in direct contact with the chemical, drawing in through the suction valve and pushing out through the discharge valve. Learn how stroke sets flow, why double ball valves are used, and what packing does.
pH Dosing System Control: Probe Placement, Lag and Stopping Overshoot
How a closed-loop pH dosing system works for acid and caustic neutralization: where to mount the pH probe, why dead time and the titration curve cause hunting, on/off versus proportional pump control, and field fixes that stop overshoot.
How a Metering Pump Works: Why a Reciprocating Pump Doses So Accurately
How a metering pump works: a diaphragm or plunger moves back and forth, each stroke draws in and pushes out a fixed volume, and two check valves keep the flow one way. Learn the suction and discharge strokes, the flow formula, and what makes a pump lose accuracy.
How a Mechanical Diaphragm Metering Pump Works: Eccentric, Push Rod and Return Spring
How a mechanical diaphragm metering pump works: a motor drives a worm gear reducer and eccentric shaft, the push rod drives the diaphragm forward to discharge, and a return spring pulls it back. See how stroke length adjustment sets flow and where spring return designs fit.
245 items · Page 19 of 25