Zhejiang Weilan Technology Co., Ltd.

Technical Articles

Selection guides, maintenance notes and application stories

Technical Articles

Three-Tank Polymer Make-Down System: How Mixing, Aging and Storage Chambers Work

A three-tank polymer make-down system splits one unit into mixing, aging and storage chambers so dry PAM is wetted, matured and fed continuously without batch interruptions. Learn what each chamber does, how solution moves between them, how the mixers differ and how to fix fish eyes, overflow and pump starvation.

Technical Articles

Metering Pump Back Pressure Valve: Keeping Accuracy When Discharge Is Near Atmospheric

A metering pump back pressure valve is needed when the discharge is close to atmospheric: open basins, injection points below the tank, very short lines. Learn why accuracy drops without one, where to mount it, how it pairs with a pulsation dampener and how to set it.

Technical Articles

Boiler Feedwater Chemical Treatment: Oxygen Scavengers, pH Control and Where Phosphate Fits

Boiler feedwater chemical treatment covers two chemical groups: oxygen scavengers that remove residual dissolved oxygen and alkalizing agents that raise feedwater pH. Phosphate is actually dosed to the drum. Learn where each chemical goes, what it does, how to configure the dosing skid and which mistakes to avoid.

Technical Articles

Boiler Dosing Pump Startup: How It Works and How to Commission It Step by Step

A boiler dosing pump is a reciprocating positive displacement pump that delivers a fixed volume per stroke, which is why it can feed small flows into high-pressure feed lines and drums. Learn why it is used, which parts matter and the full first-start sequence from checks and zero-stroke running to priming, pressurizing and calibration.

Technical Articles

What Is a Metering Pump? Definition, Key Features and How It Differs From Other Pumps

What is a metering pump? It is a positive displacement pump that delivers a set volume of liquid, adjustably and repeatably, mostly used to inject chemicals. Learn the definition, the three core features, and how it differs from a centrifugal pump.

Technical Articles

Solenoid vs Motor Driven Metering Pump: Does a Solenoid Pump Have a Motor?

Solenoid vs motor driven metering pump explained: a solenoid pump has no motor, gearbox or eccentric. A control board pulses an electromagnet that pushes the diaphragm, and a spring returns it. Learn what to look for on the cutaway drawing and how to tell the two drives apart.

Technical Articles

Plunger Pump vs Metering Pump: Same Reciprocating Action, Different Jobs

Plunger pump vs metering pump: both push liquid with a reciprocating plunger, but a pressure washer or injection pump is built for pressure and output, while a plunger metering pump adds adjustable stroke, metering-grade check valves and a stated accuracy. See how to tell them apart and when to use which.

Technical Articles

Metering Pump Turndown Ratio: What 10:1, 100:1 and 1000:1 Really Mean

Metering pump turndown ratio is the span between maximum and minimum flow over which the pump still holds its stated accuracy. Learn how 10:1, 100:1 and 1000:1 differ, why the dial range is not the turndown, how stroke length and speed combine, and how to size for it.

Technical Articles

Double Diaphragm Metering Pump: How the Intermediate Chamber Detects a Rupture

How a hydraulic double diaphragm metering pump works and how its leak alarm is triggered: sandwich vs separated diaphragms, pressure vs conductivity detection, material and pressure limits, and what to do when the alarm sounds.

Technical Articles

Metering Pump Accuracy Explained: Steady-State, Repeatability and Linearity for Hydraulic Diaphragm Pumps

Metering pump accuracy on a datasheet usually means steady-state accuracy, valid only over a stated turndown and test condition. Learn how steady-state accuracy, repeatability and linearity differ, how hydraulic diaphragm pump flow ranges are stated, and what to ask before comparing brands.