FAQ
Selection guides, maintenance notes and application stories
Plunger Metering Pump Stroke Adjustment with Frequency Control
Plunger metering pump stroke adjustment sets volume per cycle while a VFD or motor speed sets rate. Learn packing checks, low-stroke limits, and how to combine travel with frequency for high-pressure dosing.
Metering Pump Flow Adjustment: Stroke Length and Frequency Together
Metering pump flow adjustment works best when stroke length sits in a healthy band and frequency tracks load. See how to combine the two controls, why very low stroke hurts accuracy, and how to prove results with a column.
Mechanical Diaphragm Pump Flow Adjustment: Reading the Dial and Locking It
Mechanical diaphragm pump flow adjustment starts with reading the percent dial correctly, setting stroke per the manual, locking the nut, and proving flow. See how VFDs share the job and how backlash fools the scale.
Diaphragm Metering Pump Flow Adjustment While the Pump Is Running
Diaphragm metering pump flow adjustment depends on whether the model allows stroke changes under load. Learn a safe running method, how to lock the dial, and why very low stroke still hurts accuracy on diaphragm heads.
PAM Dosing Pump Not Pumping: Viscosity or a Too-Small Suction Line?
PAM dosing pump not pumping? Most cases trace to polymer solution that is too thick, a suction line that is too small or too long, a stroke rate that is too fast, or valves fouled by gel lumps.
Metering Pump Unstable Flow: Back Pressure, Pulsation and Cavitation
Metering pump unstable flow usually comes from siphoning, unbuffered pulsation, suction cavitation, poor valve sealing or a noisy control signal. Here is how to tell them apart and fix each one.
Stroke Adjustment Knob Stuck? Why It Happens and the Risk of Adjusting at Standstill
A stroke adjustment knob that will not turn usually means the pump is stopped, the lock is on, the knob is at its limit, the mechanism is dry or rusted, or internal parts are damaged. Learn the right method.
Metering Pump Low Flow: Causes and How to Fix Them
Metering pump low flow usually comes from suction lift, worn check valves, wrong stroke settings, back pressure or a tired diaphragm. Learn how to measure real output and trace the cause step by step.
Metering Pump Accuracy: Why Your Dose Is Off and How to Fix It
Poor metering pump accuracy usually comes from calibration under the wrong conditions, low or unstable back pressure, siphoning, air, worn valves or changing chemical properties. Learn how to calibrate.
Metering Pump Noise: What Knocking, Clunking and Whining Mean
Abnormal metering pump noise often points to a specific fault. Clunking usually means suction or valve trouble, metallic knocking means worn drive parts, and whining points to bearings or lubrication.
84 items · Page 7 of 9