FAQ
Selection guides, maintenance notes and application stories
Dosing System Not Dosing? Trace It From Tank to Injection Point
When a chemical dosing system stops dosing, the cause can sit in the tank, the suction line, the strainer, the metering pump, the back-pressure valve or the injection point. Here is a section-by-section check.
Dosing Pump Fault Codes: Common Alarm Meanings and How to Reset
Dosing pump fault codes differ by brand, but the alarm types are similar: low level, flow monitoring, overpressure, power, external signal, diaphragm leak and internal faults. Learn what each means.
Diaphragm Pump No Pressure: Causes and Step-by-Step Checks
A diaphragm pump no pressure problem usually comes from air in the head, sticking check valves, a relief valve set too low, a damaged diaphragm or low hydraulic oil. Learn how to check each cause.
Can a Metering Pump Run Dry? Effects on Diaphragm and Valves
Can a metering pump run dry? A short dry run rarely causes instant damage, but it brings air lock, crystallized valves and, on plunger pumps, packing wear. Learn the effects and how to prevent it.
Solenoid Metering Pump No Output: Mode, Stroke and Gas Lock
Solenoid metering pump no output? Check operating mode, stroke rate and gas lock before suction leaks and check valves. Small stroke volume makes air and a zero remote signal look like a dead pump.
Sodium Hypochlorite Dosing Gas Lock: Clear Air and Crystals
Sodium hypochlorite dosing gas lock is the usual reason a bleach feed pump strokes but residual chlorine stays flat. Learn how to vent the head, use flooded suction, clean white crystals at the injection valve, and tell weak aged bleach from a true mechanical fault.
Plunger Metering Pump No Output: Packing Leak and Valve Wear
Plunger metering pump no output often traces to packing leakage or worn suction and discharge valves. Learn when to snug packing versus replace it, how to inspect valve sets, and how dry running, crystals and discharge dead-heading cut flow on a plunger metering pump.
PAC Dosing Pump Not Delivering: Crystals and Dilution Ratio
PAC dosing pump faults on site are usually crystals in the checks or a dilution change that was never recalculated. Learn how to clean valves, keep strainers clear, recompute solution flow after a strength change, and verify suction lift, back pressure and head materials on a PAC dosing pump.
Metering Pump Not Dosing: Check From Suction to Discharge
Metering pump not dosing while the drive still moves? Walk suction, head valves, discharge, then stroke and control. Most no-flow faults sit in pipework and valves, not a dead drive unit.
Mechanical Diaphragm Pump Not Dosing: Stroke, Check Valves and Suction Lift
Mechanical diaphragm pump not dosing? Walk through stroke setting, check valves and suction lift in order before you pull the head. A field checklist for zero flow and low flow, with flooded suction tips and when to inspect the diaphragm last.
84 items · Page 8 of 9