Lango EX-B & EH-E Digital Metering Pump: Step-by-Step Operation Guide
Lango digital metering pumps (EX-B and EH-E series) are widely used in water treatment and chemical dosing skids for their clear digital displays and compact footprints. Based on our Lango EX-B and Lango EH-E listings, here is the standard five-step commissioning workflow.
1. Series Specifications
- Lango EX-B Digital Diaphragm Pump: Flow
0–30 L/h, pressure0.4–1.2 MPa. - Lango EH-E Solenoid Diaphragm Pump: Flow
31.2–75 L/h(520–1,250 mL/min) for higher-volume solenoid dosing.
2. Five-Step Startup Procedure
- Verify Piping & Valve Arrows: Confirm suction/discharge tightness and that check-valve arrows point vertically upward.
- Prime at 100% Speed: Crack the bleed valve open, run at
100%frequency for 1–2 minutes until bubble-free liquid flows, then close the bleed valve. - Select Control Mode: Choose Manual (
+ / -keypad) or4–20 mA/ Pulse external mode. - Open Discharge & Check Pressure: Verify all isolation valves are open and system pressure stays within rated limits.
- Drawdown Calibration: Run a 1-minute cylinder check under actual backpressure to confirm dosing rate.
3. Wiring & Maintenance Tips
Use shielded cable for 4–20 mA and float-switch loops, keep suction lift ≤1.5 m, and flush with clean water for 5 minutes before long-term shutdown.
Conclusion
Following the "Check Valves → Bleed at 100% → Set Mode → Verify Flow" sequence makes Lango pump commissioning fast and trouble-free. Contact our team for manuals or spare parts.
FAQ
Why does my new Lango pump click without priming?
Air is trapped in the head—open the bleed valve at 100% speed until steady liquid flows, and check suction clamps for air leaks.
What is the difference between EX-B and EH-E?
EX-B covers 0–30 L/h precision dosing, while EH-E handles higher solenoid flows from 31.2 to 75 L/h.
How do I prevent chemical siphoning after shutdown?
Install a backpressure/anti-siphon valve on the discharge line.
Can Lango pumps use dry-contact start/stop signals?
Yes—wire dry-contact relays or tank float switches to the dedicated control terminals without applying mains voltage.
How should I store the pump during long shutdowns?
Flush with clean water for 5 minutes to clear corrosive or crystallizing residue before powering down.