Mechanical Diaphragm Pumps
Ailipu JXM-D Mechanical Diaphragm Metering Pump
JXM-D mechanical diaphragm. Flow ~3.2–600 L/h, ~0.4–1.2 MPa.
Max flow
3.2 – 600 L/h
Max pressure
see model table (series max. approx. 1.2 MPa)
Turndown / accuracy
rated accuracy ±1% (stroke 30%–100%)
Wetted materials
PVC / PVDF / PTFE / SS304 / SS316L etc. optional
Protection
—
Power
single-phase 220V or three-phase 380V (depends on model)
Features
- Mechanically driven diaphragm
- Leak-free static seal
- Water & chemical dosing
Specifications
| Flow range | 3.2 – 600 L/h |
| Max pressure | see model table (series max. approx. 1.2 MPa) |
| Accuracy | rated accuracy ±1% (stroke 30%–100%) |
| Suction lift | ≤3 m water column (mechanical diaphragm) |
| Liquid temp | 15 – 85 °C (see range) |
| Viscosity | 0.3 – 2000 mm²/s (incl. solids particles) |
| Wetted materials | PVC / PVDF / PTFE / SS304 / SS316L etc. optional |
| Diaphragm | PTFE or rubber composite PTFE |
| Adjustment | 0–100% class; manual / VFD / digital or stroke controller |
| Power supply | single-phase 220V or three-phase 380V (depends on model) |
| Series flow | 0.5 – 600 L/h |
| Series pressure | 0.4 – 168 MPa |
| Brand | Ailipu |
Applications
Materials & media
| Wetted materials | PVC / PVDF / PTFE / SS304 / SS316L etc. optional |
| Diaphragm | PTFE or rubber composite PTFE |
Common chemicals: NaOCl, acids, alkalis, polymers — confirm compatibility when inquiring.
Controls & communication
| Adjustment | 0–100% class; manual / VFD / digital or stroke controller |
Models & specs
| Model | Flow | Pressure | Power | Notes | |
| JXMD-3.2/1.2 | 3.2 L/h | 1.2 MPa | 0.25 kW | stroke 1.5 mm; speed 45 min⁻¹; diaphragm φ63/36; connection DN8; power 0.25 kW; approx. 60 kg | |
| JXMD-4.5/1.2 | 4.5 L/h | 1.2 MPa | 0.25 kW | stroke 1.5 mm; speed 58 min⁻¹; diaphragm φ63/36; connection DN8; power 0.25 kW; approx. 60 kg | |
| JXMD-8/1.2 | 8 L/h | 1.2 MPa | 0.25 kW | stroke 1.5 mm; speed 106 min⁻¹; diaphragm φ63/36; connection DN8; power 0.25 kW; approx. 60 kg | |
| JXMD-10/1.2 | 10 L/h | 1.2 MPa | 0.25 kW | stroke 1.5 mm; speed 135 min⁻¹; diaphragm φ63/36; connection DN8; power 0.25 kW; approx. 60 kg | |
| JXMD-15/1.2 | 15 L/h | 1.2 MPa | 0.25 kW | stroke 4.5 mm; speed 45 min⁻¹; diaphragm φ82/45; connection DN15; power 0.25 kW; approx. 60 kg | |
| JXMD-20/1.2 | 20 L/h | 1.2 MPa | 0.25 kW | stroke 4.5 mm; speed 58 min⁻¹; diaphragm φ82/45; connection DN15; power 0.25 kW; approx. 60 kg | |
| JXMD-36/1.2 | 36 L/h | 1.2 MPa | 0.25 kW | stroke 4.5 mm; speed 106 min⁻¹; diaphragm φ82/45; connection DN15; power 0.25 kW; approx. 60 kg | |
| JXMD-46/1.2 | 46 L/h | 1.2 MPa | 0.25 kW | stroke 4.5 mm; speed 135 min⁻¹; diaphragm φ82/45; connection DN15; power 0.25 kW; approx. 60 kg | |
| JXMD-58/1.0 | 58 L/h | 1.0 MPa | 0.25 kW | stroke 7 mm; speed 45 min⁻¹; diaphragm φ110/70; connection DN15; power 0.25 kW; approx. 60 kg | |
| JXMD-75/1.0 | 75 L/h | 1.0 MPa | 0.25 kW | stroke 7 mm; speed 58 min⁻¹; diaphragm φ110/70; connection DN15; power 0.25 kW; approx. 60 kg | |
| JXMD-100/0.8 | 100 L/h | 0.8 MPa | 0.37 kW | stroke 9 mm; speed 58 min⁻¹; diaphragm φ110/70; connection DN15; power 0.37 kW; approx. 60 kg | |
| JXMD-138/0.7 | 138 L/h | 0.7 MPa | 0.37 kW | stroke 7 mm; speed 106 min⁻¹; diaphragm φ110/70; connection DN15; power 0.37 kW; approx. 60 kg | |
| JXMD-175/0.7 | 175 L/h | 0.7 MPa | 0.37 kW | stroke 9 mm; speed 106 min⁻¹; diaphragm φ110/70; connection DN15; power 0.37 kW; approx. 60 kg | |
| JXMD-225/0.6 | 225 L/h | 0.6 MPa | 0.37 kW | stroke 9 mm; speed 135 min⁻¹; diaphragm φ110/70; connection DN25; power 0.37 kW; approx. 60 kg | |
| JXMD-300/0.6 | 300 L/h | 0.6 MPa | 0.55 kW | stroke 11 mm; speed 106 min⁻¹; diaphragm φ116/80; connection DN25; power 0.55 kW; approx. 60 kg | |
| JXMD-380/0.5 | 380 L/h | 0.5 MPa | 0.55 kW | stroke 11 mm; speed 135 min⁻¹; diaphragm φ116/80; connection DN25; power 0.55 kW; approx. 60 kg | |
| JXMD-415/0.5 | 415 L/h | 0.5 MPa | 0.55 kW | stroke 12 mm; speed 135 min⁻¹; diaphragm φ116/80; connection DN25; power 0.55 kW; approx. 60 kg | |
| JXMD-500/0.4 | 500 L/h | 0.4 MPa | 0.55 kW | stroke 12 mm; speed 168 min⁻¹; diaphragm φ116/80; connection DN25; power 0.55 kW; approx. 60 kg | |
| JXMD-500/0.5 | 500 L/h | 0.5 MPa | 0.75 kW | stroke 12 mm; speed 168 min⁻¹; diaphragm φ116/80; connection DN25; power 0.75 kW; approx. 60 kg | |
| JXMD-600/0.4 | 600 L/h | 0.4 MPa | 0.75 kW | stroke 14 mm; speed 168 min⁻¹; diaphragm φ116/80; connection DN25; power 0.75 kW; approx. 60 kg |
Dimensions & installation
Dimensional drawings available on request (CAD / PDF).
Downloads
Related / accessories

Mechanical Diaphragm Pumps
NDWS Series Mechanical Diaphragm Metering Pump

Mechanical Diaphragm Pumps
NDWL Series Mechanical Diaphragm Metering Pump

Mechanical Diaphragm Pumps
KD Series Mechanical Diaphragm Metering Pump (Cheon-Sei / KEMPION)

Mechanical Diaphragm Pumps
SEKO Kosmo MM1 Mechanical Diaphragm Pump

Mechanical Diaphragm Pumps
ND2000 Series Mechanical Diaphragm Metering Pump

Mechanical Diaphragm Pumps
HND Series Mechanical Diaphragm Metering Pump
Related solutions
Municipal Wastewater Dosing
Integrated dosing systems combining metering pumps and online water quality monitoring for coagulation, disinfection and dephosphorization.
Smart Secondary Supply Disinfection
Unattended pump-room retrofits: hypochlorite dosing with online residual chlorine/pH and remote alarms.
Hospital Wastewater Disinfection
GB18466-compliant disinfection dosing with online residual chlorine and exceedance alarms.
Related case studies

Wastewater
Municipal WWTP PAC Dosing Upgrade
Mechanical diaphragm pumps with online turbidity monitoring cut chemical consumption by 15%.

Chemical
Chemical Park Acid/Alkali Neutralization
Corrosion-resistant mechanical diaphragm pumps dosing concentrated acid/alkali with closed-loop pH control — 99% compliance.

Drinking Water
Water Plant NaOCl Disinfection System
Complete dosing skid with online finished-water chlorine monitoring keeps byproducts controlled.
Need help selecting?
Share duty (flow, pressure, media, controls) — we reply within 1 business day.