RO Antiscalant Dosing Calculation & Preventing Biofouling in Chemical Day Tanks
Underdosing RO antiscalant scales tail-end membrane elements with CaCO3/CaSO4, while stagnant diluted chemical tanks breed bacterial slime that biofouls cartridge filters and membranes faster than mineral scale.
1. Sizing Math Example
For a 20 m³/h RO permeate system at 75% recovery, feed flow is 26.7 m³/h. At a 3.0 mg/L target dose, pure chemical demand is only 80 g/h (~0.07 L/h). Diluting 20× with RO permeate brings the dosing rate to 1.4 L/h, matching a reliable 2–5 L/h @ 5–10 bar PVDF/PVC solenoid pump.
2. Stopping Tank Biofouling
- Dilute Strictly with RO Permeate: Never use raw or tap water containing hardness ions and bacteria.
- 3–5 Day Batch Sizing: Phosphonate antiscalants act as microbial nutrients; mix only 3–5 days of supply (≤3 days in summer) in a covered, opaque PE tank and sanitize biweekly.
Conclusion
Accurate feed-flow dilution, RO-permeate makeup, and short batch turnover protect RO membranes from both scale and biofouling. Visit Products or Contact Us.
FAQ
Should antiscalant and SMBS dechlorinator share an injection tee?
No. Separate their injection ports by at least 0.5–1.0 m upstream of the cartridge filter to prevent concentrated polymer/bisulfite precipitation.
Should the antiscalant pump run during RO low-pressure flush?
No. Interlock the dosing pump with permeate production so chemical is not wasted during flushing.