Iwaki Metering Pump Wiring: Power, Pulse, STOP and Analog Signals

Iwaki metering pump wiring for the EHN series: 100-240 VAC power, voltage-free pulse and STOP inputs, the EHN-YN 0-20 mA analog input, FCM input, alarm output and sensor supply, plus common wiring mistakes.

Technical Articles

Boiler Chemical Injection Point Guide: Feedwater, Drum and Condensate

Choosing a boiler chemical injection point depends on where each chemical has to work: oxygen scavenger and amine in the feedwater after the deaerator, phosphate into the steam drum, and neutralizing amine in the condensate line. Learn why, plus where boil-out chemicals go.

Technical Articles

Dosing Pump Type: What Kind of Pump Is a Dosing Pump?

What type of pump is a dosing pump? Most are reciprocating positive displacement pumps. See where each dosing pump type sits in pump classification, how they differ and why it matters for installation.

Technical Articles

Solenoid Metering Pump Commissioning: First Start-Up Step by Step

Solenoid metering pump commissioning in six steps: pre-power checks, supply, RCD and earthing, water trial and priming, calibration column test, external signal and alarm tests, then a handover record for operators.

Technical Articles

ProMinent Pump Wiring Guide: Power, External Control and Level Input

ProMinent pump wiring comes down to four groups: power supply, external control (pulse or 4–20 mA), level switch input and alarm or relay output. Learn the logic, typical mistakes and safety rules.

Technical Articles

ProMinent Pump Model Code Explained: Series, Identcode and Head Materials

How to read a ProMinent pump model code: the series name tells you the drive, and the identcode lists capacity class, liquid end material, valves, connections, power supply and control options.

Technical Articles

ProMinent Pump Adjustment: Stroke Length, Frequency and External Mode

A practical ProMinent pump adjustment guide: set stroke length first, fine-tune with stroke frequency, then calibrate. Learn why short strokes cause errors and how external pulse or 4–20 mA mode works.

Technical Articles

Mechanical Diaphragm Pump Installation Plan: Base, Piping and Electrics

A mechanical diaphragm pump installation plan you can adapt: location, concrete base or steel frame, anchoring, suction and discharge piping with supports, motor and VFD wiring, service space, oil fill and acceptance.

Technical Articles

Chemical Dosing Safety Procedures for Wastewater Treatment Plants

A practical framework for chemical dosing safety procedures at wastewater plants: general rules, receiving and storage, solution make-up, dosing operation, spill response and handover, plus chemical-specific notes for PAC, polymer, carbon source and hypochlorite.

Technical Articles

Polymer Dosing System Operation: Make-Down, Feed and Cleaning SOP

A practical polymer dosing system operation SOP for PAM units: pre-start checks, polymer make-down, metering pump feed, flushing, changeover and safety rules your operators can follow shift by shift.