Refinery and petrochemical flare headers are hard to meter: gas velocity swings from 0.03 m/s purge flow to over 100 m/s emergency blowdown while composition changes constantly. Based on our FLOWSIC100 Flare-XT page, here is how it handles flare service.

1. Key Technical Advantages

  • Non-intrusive ultrasonic transducers track both low purge flows and peak relief events with zero pressure drop across the flare header.
  • The meter calculates average molecular weight directly from acoustic speed, so it does not rely on fixed gas tables when composition shifts.
  • Optional ball-valve retraction assemblies let technicians pull and clean probes online without shutting down the flare line.

2. Installation Best Practices

Keep standard straight pipe runs (typically 10D upstream and 5D downstream on DN150 to DN1200 headers), mount away from high-frequency relief-valve noise, and drain condensate low points so liquid slugs never cover the lower transducer.

Conclusion

Endress+Hauser FLOWSIC100 Flare-XT gives refineries reliable emissions reporting and leak detection without obstructing safety flare headers. Contact our team for sizing and datasheets.

FAQ

How is FLOWSIC100 Flare-XT installed on large DN600+ headers?

Transducers mount through angled weld-on nozzles on the existing pipe rather than replacing a full spool.

Why is zero pressure drop critical on flare headers?

Any flow restriction raises backpressure on upstream safety relief valves. Non-intrusive ultrasonic sensors avoid that hazard.

Does shifting gas composition require manual reprogramming?

No. Measured speed of sound plus pressure and temperature inputs dynamically track molecular weight changes.

Can fouled probes be cleaned without shutting down the flare?

Yes, with retractable ball-valve assemblies, probes can be extracted safely while the line stays live.

Do you supply FLOWSIC600-XT and FLOWSIC610 as well?

Yes. Weilan supplies the full Endress+Hauser FLOWSIC gas and Promag liquid flowmeter lineup.