Fixing Gas-Lock in Sodium Hypochlorite Pumps & Priming Issues in Antiscalant Pumps
Two of the most frequent field headaches in water treatment are gas-locking in sodium hypochlorite dosing pumps and loss of prime in RO antiscalant pumps. Both result in zero chemical feed, but their root causes differ. Here is how to fix both permanently.
1. Stopping Bubbles in Sodium Hypochlorite Dosing
Sodium hypochlorite decomposes into chlorine gas when exposed to sunlight, heat (>30 °C), or suction vacuum:
- Switch to Flooded Suction: Mount the pump below the lowest tank liquid level so gravity keeps positive head on the suction check valve.
- Shade & Cool the Tank: Use opaque PE tanks away from direct sunlight or steam lines.
- Select Gas-Handling Pumps: Consider pumps with automatic deaeration or straight-through flow paths, such as Grundfos DDA (
SlowMode) or Neptune MP7000.
2. Fixing Antiscalant Pumps That Won't Prime
For compact solenoid pumps like the New Dose DFD:
- Bleed at 100% Frequency: Open the manual bleed valve counterclockwise while running at full speed until steady, bubble-free flow exits the return line.
- Clean Sticky Check Valves: Warm-water soak foot and check valves if viscous antiscalant residue glues the balls to their seats.
- Check Injection Point Pressure: Ensure pump rated pressure exceeds RO feed line pressure (
0.2–0.5 MPa) and that the injection quill check valve isn't fouled. - Operate at 30%–80% Frequency: Dilute chemical if needed so the pump doesn't run at ultra-low SPM where valve seating lags.
3. Essential Discharge Accessories
Install a relief valve, backpressure valve, and injection check valve on the discharge line to prevent siphoning and stabilize check-valve seating.
Conclusion
Eliminating sodium hypochlorite gas-lock requires flooded suction and shaded tanks, while antiscalant priming relies on clean check valves, proper bleeding, and adequate backpressure. Contact our team for anti-gas-lock dosing skids.
FAQ
Why does my hypochlorite pump lose prime specifically at midday?
Higher midday temperatures accelerate off-gassing inside the tank and suction line, triggering vapor lock—especially under suction lift.
Why does the antiscalant pump click loudly without pumping liquid?
Air is trapped in the pump head (open the bleed valve) or debris is holding a check-valve ball off its seat.
Should I install a backpressure valve on an RO antiscalant line?
Yes, whenever there is risk of siphoning or low system backpressure; it also improves dosing repeatability.
What tubing material resists sodium hypochlorite best?
Use opaque or UV-stabilized PE/PTFE tubing rather than standard clear PVC, which hardens and cracks over time.
Do you supply complete skid-mounted hypochlorite dosing systems?
Yes, Weilan builds turnkey skids with shaded tanks, level switches, gas-handling pumps, and safety/backpressure valves.