SEKO DMS 200 Metering Pump Manual: Wiring, Calibration, and Priming
The SEKO DMS 200 solenoid diaphragm metering pump is widely used in RO pretreatment, swimming pool disinfection, and compact cooling water dosing skids. Getting the electrical interlock, level switch wiring, and initial air priming right ensures reliable flow from day one.
This guide covers the core specifications, wiring setup, dual-range dial adjustment, and priming steps based on the official SEKO DMS 200 manual.
1. SEKO DMS 200 Specifications and Wetted Materials
Built with an IP65 fiberglass-reinforced polypropylene housing, the SEKO DMS 200 accepts universal 100–240V AC 50/60Hz power input without external transformers.
- Flow and pressure range: Typical configurations cover
2 to 9 L/h(for example,4 L/h @ 10 bar,5 L/h @ 7 bar, or9 L/h @ 4 bar), matching small pressurized injection lines. - Standard chemical resistance: Features a molded
PVDFpump head, purePTFEdiaphragm, and double ceramic ball check valves rated for acids, sodium hypochlorite, and oxidizing biocides.
2. Power Interlock and Low-Level Float Wiring
Wire the three-core power cable (L, N, PE) to a switched single-phase supply. On RO skids or pool circulation loops, interlock the pump supply with the main feed pump contactor so dosing stops automatically whenever water flow stops.
Connect a PP or PVDF float level switch to the two-pin LEVEL dry-contact input on the SEKO DMS 200. When tank liquid drops to 10 cm from the bottom, the pump halts and triggers the low-level LED alarm to prevent dry running and air-locking.
3. Dual-Range Flow Control and Priming Procedure
The front panel combines a 0–100% stroke-frequency dial with a 100% / 20% range selector switch:
- Keep the switch at
100%for normal operation, or flip to20%when dosing tiny chemical volumes below20%rated output for five times finer adjustment resolution. - Before pressurized injection, set frequency to
100%, turn the manual bleed knob on the pump head counterclockwise, and run until a solid stream without bubbles exits the clear bleed return tube to the tank.
Conclusion
Combining proper main-pump electrical interlock, low-level protection, and bleed priming keeps the SEKO DMS 200 dosing accurately. Visit our Products page or Contact Us for datasheets and spare kits.
FAQ
Why does my SEKO DMS 200 click loudly without pumping liquid?
The clicking sound is normal solenoid coil actuation. If no chemical moves, open the manual bleed knob to purge trapped air and inspect suction tubing connections for air leaks.
Does the DMS 200 accept a 4-20mA analog input signal?
No. Standard DMS 200 models offer manual frequency adjustment and low-level input only; choose SEKO Tekna APG or Kompact AML for 4-20mA or pulse control.
Will running dry damage the SEKO DMS 200 coil?
Brief dry operation rarely burns the coil immediately, though trapped air causes vapor lock. Installing a low-level float switch prevents air-lock headaches.
What tubing sizes come standard with the DMS 200?
Standard kits include 4x6 mm flexible PVC suction tubing and rigid 4x6 mm PE discharge tubing. Never install the softer suction tubing on the pressurized discharge side.
Do you supply genuine SEKO DMS 200 spare diaphragms and PVDF heads?
Yes. We stock complete DMS 200 pumps along with genuine PTFE diaphragms, ceramic check valves, foot valves, and injection valves.