Pulsafeeder Metering Pump Not Pumping? Stroke Adjustment & Troubleshooting
Pulsafeeder metering pumps are widely relied upon in chemical processing, power generation, and water treatment. However, field operators occasionally run into loss of prime or discharge failures. Using official specifications for Pulsa GLM and PulsaMax, this guide covers how to restore flow and adjust stroke length properly.
1. Core Series Specifications
- Pulsa GLM (Mechanical Diaphragm): Flow
10–3,600 L/h, max discharge pressure12 bar, stroke adjustable0–100%at1%resolution. - PulsaMax (Hydraulic Diaphragm): High-pressure leak-free models—for example,
880up to370 L/hand124 bar, and7120up to1,000 L/hand34 bar.
2. Five Common Causes When a Pulsafeeder Pump Fails to Discharge
Air Lock or Excessive Suction Lift
Trapped air prevents the diaphragm from building suction vacuum. Set stroke to 100%, open the bleed/return line to atmospheric pressure for 1–3 minutes, and re-engage system backpressure once bubble-free flow appears.
Fouled or Reversed Check Valves
Crystallized PAC or sodium hypochlorite lodges under valve balls. Depressurize, clean the balls and seats, and reinstall with body arrows pointing vertically upward.
Suction Line Air Leaks or Clogged Strainer
Inspect suction tubing clamps and foot-valve strainers positioned 5–10 cm above the tank bottom.
Low Hydraulic Oil (PulsaMax Only)
Check the sight glass for low or emulsified hydraulic oil and verify that the internal relief valve is not stuck open.
Improper System Backpressure
Install a backpressure valve to prevent siphoning and a safety relief valve to prevent dead-heading.
3. Proper Stroke Adjustment
Adjust the mechanical stroke knob while the pump is running to avoid stressing the eccentric drive. Keep operating stroke within 20%–100% (ideally ≥30%) for linear dosing accuracy.
Conclusion
Following the "Bleed Air → Check Valves → Suction Seal → Hydraulic Oil/Backpressure" sequence solves most Pulsafeeder flow issues. For spare diaphragms or sizing help, contact our team.
FAQ
Why does dosing accuracy drop below 10% stroke?
At very short strokes, check-valve ball lift is too small for consistent seating; pair with a VFD or select a smaller liquid end.
How often should PulsaMax hydraulic oil be changed?
Replace after the first 500 hours of break-in, then every 4,000–5,000 operating hours or annually.
When should I choose Pulsa GLM vs. PulsaMax?
Choose GLM for standard duties ≤12 bar; choose PulsaMax for high-pressure (>15 bar) or hazardous chemical applications.
What triggers a fault light on Pulsafeeder skids?
Common triggers include motor overload, low tank level interlocks, or VFD phase faults.
Do you supply genuine Pulsafeeder spare parts?
Yes, Weilan supplies complete Pulsafeeder pumps as well as OEM diaphragms, check valves, and relief valves.