MBR Chemically Enhanced Backwash (CEB): Pump Sizing and Bleach-Acid Interlocks
Hollow-fiber MBR membranes rely on periodic chemically enhanced backwash (CEB)—injecting concentrated sodium hypochlorite (300–500 ppm active chlorine) or citric acid (1,000–2,000 ppm) directly into the backwash header—to control transmembrane pressure (TMP). Sizing your MBR CEB dosing pump to match the high instantaneous backwash pump flow prevents under-cleaning and membrane damage.
Here is the sizing formula and PLC safety interlock checklist.
1. Calculating CEB Chemical Pump Capacity
Using 10% (100,000 ppm) sodium hypochlorite at target concentration $C = 500 ext{ ppm}$ into a backwash flow $Q_{ ext{bw}}$ (m³/h):
$$Q_{ ext{pump}} ext{ (L/h)} = rac{Q_{ ext{bw}} ext{ (m³/h)} imes 1000 imes C}{100,000}$$
For a 20 m³/h backwash pump at 500 ppm, $Q_{ ext{pump}} = 100 ext{ L/h}$—requiring a 120–150 L/h @ 3–5 bar mechanical diaphragm pump (KEMPION KD, SEKO Spring MS1, or New Dose NDWS). Smaller 5 m³/h package MBR skids (25–30 L/h) can use Tekna APG 803 or DFD-60 solenoid pumps.
2. PVDF Materials and Mandatory Bleach-Acid Interlocks
- Use PVDF heads, PTFE diaphragms, and FKM seals on both bleach and citric acid pumps (avoid stainless heads).
- Flow-switch and mutual-exclusion interlocks:
PLClogic must allow MBR CEB dosing pump operation only when the backwash pump is running with confirmed flow—and must strictly forbid simultaneous bleach and acid dosing (separated by a clean-water flush) to prevent toxic chlorine gas evolution.
Conclusion
Sizing capacity to instantaneous backwash flow, specifying PVDF+FKM wetted parts, and enforcing PLC flow and bleach-acid interlocks ensure safe MBR CEB dosing pump operation. Visit Products or Contact Us for dual-pump CEB packages.
FAQ
Are inline CEB pumps different from offline MBR recovery-clean pumps?
Yes. Recovery cleaning mixes batches in a soak tank, whereas inline CEB injects concentrated chemical over a short 5–15 minute backwash pulse, requiring higher instantaneous L/h capacity.
Do CEB pumps need backpressure valves on the backwash line?
Yes. Because backwash headers sit at zero pressure between cycles, install a 0.15–0.2 MPa backpressure valve and injection check valve so concentrated bleach cannot siphon into idle membranes.
Can bleach and citric acid injection valves share the same tee?
Separate them by at least 50 cm along the header upstream of a UPVC static mixer so concentrated chemical dilutes completely before hitting hollow fibers.
Will 10-minute CEB cycles harm a three-phase mechanical diaphragm pump?
No, a few cycles per day or week are well within standard motor thermal limits; stop the dosing pump 30 seconds before the backwash pump to flush the header clean.