FGD Desulfurization Wastewater: Lime Slurry and Organosulfide Pump Selection

Author: Zhejiang Weilan Technology Co., Ltd.Source: Official sitePublished: Category: News
Summary: Preventing valve wear and plugging in power-plant FGD three-tank wastewater treatment when dosing hydrated lime slurry, TMT-15, PAC, and PAM.

Coal-fired power plant and steel mill flue-gas desulfurization (FGD) wastewater carries high suspended gypsum, 10,000–20,000 mg/L chlorides, and heavy metals through a three-stage neutralization, precipitation, and flocculation train. Specifying FGD wastewater dosing pumps correctly prevents daily lime-slurry plugging and chloride pitting.

Here are the wetted-material and piping rules for each reaction tank.

1. Matching Pumps Across the Three-Tank Train

  1. Neutralization tank (5%–10% lime slurry or caustic): Never use fast solenoid pumps on lime slurry. Specify slow-stroking (58–72 SPM) mechanical diaphragm pumps (KEMPION KD or Doseuro D, 100–1,000 L/h @ 3–5 bar) with alumina ceramic balls, EPDM seals, a < 0.5 m tap off a continuously pumped lime recirculation loop, and a clean-water flush tee.
  2. Precipitation tank (organosulfide TMT-15 / DTCR): Specify PVC or PVDF heads with EPDM seals and zero copper or carbon-steel fittings.
  3. Flocculation tank (FeCl3 / PAC and PAM): Use all-plastic PVDF + FKM pumps for ferric chloride/PAC, and low-SPM mechanical diaphragm or progressive cavity pumps for PAM.

2. Two Anti-Plugging Rules for Lime Slurry Piping

  • Omit narrow diaphragm backpressure valves: When discharging into an open atmospheric tank, terminate rigid piping above peak tank level in free-fall drop rather than using narrow backpressure orifices that plug with lime grit.
  • Flush with clean water before shutdown: Whenever stopping a lime pump for over 1 hour, run clean water through the head and line for 3–5 minutes.

Conclusion

Slow-stroking recirculation taps for lime, all-plastic PVDF heads for chlorides/organosulfides, and strict flush routines keep FGD wastewater dosing reliable. Visit Products or Contact Us for heavy-duty power-plant dosing packages.

FAQ

Can caustic soda replace lime slurry in FGD three-tank neutralization?

20%–30% caustic is far cleaner and never plugs check valves, though lime costs roughly one-fifth as much and helps precipitate fluoride and sulfate.

Why did plastic valve seats wear grooved after 6 months on lime slurry?

Unscreened lime grit abrades soft seats; screen hydrated lime through 20–40 mesh baskets and specify wear-resistant PVDF or ceramic seats.

Can organosulfide (TMT) and PAC be dosed into the same tank compartment?

No. Neutralize first (pH 8.5–9.5), react TMT completely in Tank 2, and then add PAC/ferric and PAM in Tank 3.

What motor enclosure rating is best for wet FGD wastewater rooms?

Specify IP55 three-phase motors and IP54/IP65 stainless steel control cabinets.

Do you supply low-SPM lime slurry diaphragm pumps and screw pumps?

Yes, we supply slow-speed KEMPION KD and Doseuro D diaphragm pumps, EPDM kits, and progressive cavity polymer/slurry pumps.