Point Level Switches
Endress+Hauser FTL64 Vibronic Point Level Switch for Liquids
Endress+Hauser FTL64 Vibronic Point Level Switch for Liquids. Applications: high/low level alarm and overfill protection in tanks; pump dry-run protection.
Max flow
—
Max pressure
—
Turndown / accuracy
—
Wetted materials
316L, Hastelloy
Protection
IP66/68
Power
—
Features
- Vibronic Point Level Switch for Liquids
- Process temperature: -60...+280°C
- Ingress protection: IP66/68
Specifications
| Brand | Endress+Hauser |
| Model | FTL64 |
| Product type | liquid switch |
| Process temperature | -60...+280°C |
| Process connection | thread, flange |
| Wetted materials | 316L, Hastelloy |
| Ingress protection | IP66/68 |
| Instrument design | integral; optional extension tube |
Applications
Materials & media
| Wetted materials | 316L, Hastelloy |
Common chemicals: NaOCl, acids, alkalis, polymers — confirm compatibility when inquiring.
Controls & communication
Control options are listed in notes or confirmed on inquiry.
Models & specs
| Model | |
| FTL62 | |
| FTL63 | |
| FTL64 |
Dimensions & installation
Dimensional drawings available on request (CAD / PDF).
Downloads
Related / accessories

Point Level Switches
Endress+Hauser FTL63 Vibronic Point Level Switch for Liquids

Point Level Switches
Endress+Hauser FTL62 Vibronic Point Level Switch for Liquids

Point Level Switches
Endress+Hauser FTL41 Vibronic Point Level Switch for Liquids

Point Level Switches
Endress+Hauser FTL43 Vibronic Point Level Switch for Liquids

Point Level Switches
Endress+Hauser FTL51B Vibronic Point Level Switch for Liquids

Point Level Switches
Endress+Hauser FTL51H Vibronic Point Level Switch for Liquids
Related solutions
Smart Secondary Supply Disinfection
Unattended pump-room retrofits: hypochlorite dosing with online residual chlorine/pH and remote alarms.
Power Plant Boiler Water
Ammonia, hydrazine and phosphate dosing with sampling monitoring to prevent corrosion and scaling.
Industrial Cooling Water
Scale & corrosion inhibitor dosing for power and metallurgy cooling systems with online pH/conductivity monitoring.
Related case studies

Chemical
Chemical Park Acid/Alkali Neutralization
Corrosion-resistant mechanical diaphragm pumps dosing concentrated acid/alkali with closed-loop pH control — 99% compliance.

Drinking Water
Water Plant NaOCl Disinfection System
Complete dosing skid with online finished-water chlorine monitoring keeps byproducts controlled.

Power
Power Plant Cooling Water Dosing
Automatic antiscalant dosing with pH interlock eliminated heat-exchanger scaling.
Need help selecting?